Elevator Modernization RFP Template
Instructions: Replace all [BRACKETED] text with your building-specific information. Delete any sections that don't apply to your project.
Section 1: Building Information
| Field |
Your Information |
| Property Name |
[PROPERTY NAME] |
| Address |
[FULL ADDRESS] |
| Number of Floors |
[X] |
| Number of Elevator Units |
[X] |
| Current Equipment Manufacturer |
[MANUFACTURER] |
| Current Equipment Model |
[MODEL] |
| Year Installed (approx.) |
[YEAR] |
| Average Daily Traffic |
[ESTIMATED PASSENGERS/DAY] |
| Building Type |
[Office / Residential / Mixed-Use / Retail / Other] |
Primary Contact:
- Name: [CONTACT NAME]
- Title: [TITLE]
- Email: [EMAIL]
- Phone: [PHONE]
Section 2: Project Scope Requirements
2.1 Modernization Scope
Select one:
- [ ] Controls-Only Modernization - Controller, selector, operating panel, call stations, door operator
- [ ] Full Modernization - Complete system: controller, door operator, fixtures, cab interior, signals, pit equipment
- [ ] Custom Scope - See mandatory inclusions below
2.2 Mandatory Inclusions
All proposals MUST include:
- [ ] Controller replacement with [OPEN-PROTOCOL / SPECIFY BRAND] equipment
- [ ] Door operator replacement
- [ ] Car operating panel replacement
- [ ] Hall buttons and lanterns (all floors)
- [ ] Position indicators
- [ ] Pit equipment as required by code
- [ ] Testing and state acceptance (all permit fees)
- [ ] [ADD ADDITIONAL REQUIREMENTS]
2.3 Optional Inclusions (Price Separately)
Provide separate line item pricing for each:
- [ ] Car interior refinish/replacement
- [ ] Hoistway lighting upgrade
- [ ] ADA compliance upgrades (specify: [DETAILS])
- [ ] Cab lighting (LED upgrade)
- [ ] Security intercom integration
- [ ] Destination dispatch system
- [ ] [ADD ADDITIONAL OPTIONS]
2.4 Exclusions
The following are explicitly NOT part of this project:
- [LIST ANY EXCLUSIONS]
- [e.g., "Hoistway structural modifications"]
- [e.g., "Electrical service upgrades beyond machine room"]
Section 3: Timeline Requirements
| Milestone |
Date |
| RFP Responses Due |
[DATE] |
| Vendor Selection Target |
[DATE] |
| Contract Execution Target |
[DATE] |
| Preferred Construction Start |
[DATE] |
| Required Completion Date |
[DATE] |
Working Hours:
- Standard Hours: [HOURS, e.g., "7:00 AM - 5:00 PM Monday-Friday"]
- Weekend Work: [Available at premium / Not available]
- After-Hours Work: [Available at premium / Not available]
- Building Access Requirements: [ANY SPECIAL ACCESS PROCEDURES]
Section 4: Proposal Format Requirements
4.1 Required Sections
All proposals MUST include the following sections in this order:
- Executive Summary (1 page maximum)
- Company Qualifications
- State contractor license number
- Years in business
- Certifications (NAESA, CET, etc.)
- Local service presence (office location, technician count)
- References (see Section 5.2)
- Proposed Scope of Work
- Detailed component list
- Equipment specifications
- Work methodology
- Project Timeline
- Milestone schedule or Gantt chart
- Lead time for equipment
- Estimated duration per unit
- Pricing (see format below)
- Warranty Terms
- Post-Installation Service Options (optional to include)
- Exclusions (what is NOT included)
4.2 Pricing Format
Provide pricing in the following table format:
| Line Item |
Price |
| Base Modernization (all mandatory inclusions) |
$ |
| [Optional Item 1] |
$ |
| [Optional Item 2] |
$ |
| [Optional Item 3] |
$ |
| [Optional Item 4] |
$ |
| Permit Fees (if separate) |
$ |
| Total (Base Only) |
$ |
| Total (All Options Included) |
$ |
Payment Terms: Provide your standard payment schedule (e.g., 30% deposit, 40% at equipment delivery, 30% at completion).
4.3 Warranty Requirements
Minimum warranty requirements:
- Controller: [X] years parts and labor (minimum 2 years)
- Door Operator: [X] years parts and labor (minimum 2 years)
- All Other Components: [X] years parts and labor (minimum 1 year)
Specify any warranty limitations or exclusions.
Section 5: Vendor Qualifications
5.1 Required Qualifications
All vendors must meet the following minimums:
- [ ] Licensed elevator contractor in [STATE]
- [ ] Minimum [X] years in business
- [ ] Minimum [X] completed modernizations in last 3 years
- [ ] General Liability Insurance: $[X] minimum
- [ ] Workers Compensation Insurance: $[X] minimum
- [ ] Bonding capacity: $[X] minimum
5.2 References Required
Provide 3 references for similar projects:
Reference 1:
- Building type: [Similar to yours, e.g., "Class A Office"]
- Project scope: [Similar to your scope, e.g., "Full modernization, 2 elevators"]
- Completed within last 3 years
- Contact name, phone, email
Reference 2:
- Same requirements as above
Reference 3:
- Same requirements as above
Section 6: Evaluation Criteria
Proposals will be scored on the following criteria:
| Criterion |
Weight |
Description |
| Technical Approach |
25% |
Scope comprehensiveness, equipment quality, methodology |
| Pricing |
30% |
Total cost, payment terms, value for scope |
| Timeline |
15% |
Ability to meet required dates, realistic schedule |
| Qualifications & References |
20% |
Experience, references, local presence |
| Warranty & Service Terms |
10% |
Warranty coverage, post-installation support options |
Total: 100%
Critical Questions (Must Be Answered)
- Is the proposed controller open-protocol or proprietary? What does this mean for post-warranty service options?
- What is your local service presence? How many technicians within [X] miles?
- How do you handle change orders if unforeseen conditions are discovered?
- What is your approach to minimizing tenant disruption during construction?
Section 7: Submission Instructions
Submit Proposals To:
- Email: [EMAIL ADDRESS]
- Or Mail: [PHYSICAL ADDRESS]
- Or Portal: [ONLINE SUBMISSION URL]
Submission Deadline: [DATE and TIME, with timezone]
Questions:
- Direct all questions to: [CONTACT NAME, EMAIL, PHONE]
- Question Deadline: [DATE] - Questions received after this date may not receive response
- All questions and answers will be shared with all bidders
Site Visit:
- [ ] Mandatory site visit scheduled for [DATE, TIME, LOCATION]
- [ ] Optional site visit available upon request
- RSVP to [CONTACT] by [DATE]
Late Submissions: Proposals received after the deadline will not be considered.
Appendix A: Current Equipment Details
Provide any available documentation:
- Most recent annual inspection report
- Current maintenance contract summary
- Known open violations or deficiencies
- Recent callback history (if available)
- Equipment nameplate photos
Appendix B: Site Conditions
Note any special conditions:
- Machine room location and access
- Pit depth and condition
- Hoistway dimensions (if relevant)
- Known structural limitations
- Freight access for equipment delivery
- Union labor requirements (if applicable)
Template provided by ElevatorBlueprint.com - The Property Manager's Guide to Elevator Management
Questions about using this template? Visit elevatorblueprint.com/tools/contract-scanner for expert assistance.