EB ElevatorBlueprint
Due Diligence • Free Resource

CRE Attorney's Elevator Risk Checklist

Commercial Real Estate Due Diligence

Prepared For
____________________________
Date
____________________________
Property
____________________________
Source
ElevatorBlueprint.com
01 Documentation Review

Documentation Review

Request current CT Certificate of Operation (CGS §29-196) for each elevator unit — confirm it is not lapsed or conditionally issued
CGS §29-196 • Required for legal elevator operation in CT
Obtain DAS registration records or original installation permit to confirm equipment age
CT Dept. of Administrative Services
Request the last two inspection reports from the CT Department of Administrative Services (DAS)
DAS Elevator Division
Obtain Category 3 test records — verify test date is within the prior 36 months
Overdue = inherited buyer expense
$2K–$8K
Obtain Category 5 test records — verify test date is within the prior 60 months
Overdue = inherited buyer expense
$2K–$8K
Request the current elevator service contract — confirm term, auto-renewal date, assignability, and scope of coverage vs. items billed separately
Contract • Check assignability clause
Request any modernization proposals, condition assessments, or capital estimates provided to seller by the current service company
Undisclosed estimates = contingent exposure
Confirm the Maintenance Control Program (MCP) exists, is current, and is maintained on-site in the machine room per ASME A17.1-2013
ASME A17.1-2013 • Must be physically present
02 Physical Condition

Physical Condition Indicators

Confirm elevator type: hydraulic or traction — hydraulic units in pre-1990 commercial buildings require immediate single-bottom cylinder inquiry
Equipment classification • Determines risk profile
For hydraulic units: determine whether the below-ground cylinder is single-bottom or double-bottom — single-bottom cylinder replacement is the highest-capital-exposure risk in CT elevator due diligence
ASME A17.1-2013 • Mandatory replacement for non-compliant units
$15K–$60K
Verify that the Certificate of Operation is posted inside the elevator cab as required
CT requirement • Visual compliance check
Confirm the MCP binder is physically present in the machine room — absence is a non-compliance indicator regardless of documentation submitted
On-site verification required
Verify two-way communication system in the cab includes both audio and text capability — CT requires this above the ASME A17.1 baseline; absence creates ADA liability exposure
CT exceeds ASME baseline • ADA liability
Note any visible deferred maintenance: worn cab finishes, door operation issues, and abnormal noise are indicators of underlying mechanical condition
Visual inspection indicators
03 Compliance

Compliance & Permit Status

Confirm Certificate of Operation renewal is current — CT requires renewal every 2 years ($240 fee); a lapsed certificate authorizes DAS to order same-day shutdown
2-year cycle • $240 renewal fee • Shutdown risk if lapsed
Confirm DAS inspection is current — CT inspection cycle is every 18 months; an overdue inspection may indicate lapsed operational authority
18-month cycle • CT DAS Elevator Division
Verify compliance with CT adoption of ASME A17.1-2013 (effective 2018): pre-1990 commercial hydraulic elevators with single-bottom below-ground cylinders are subject to mandatory replacement
ASME A17.1-2013 • Effective CT 2018 • Non-discretionary capital expenditure
$15K–$60K
Confirm no open violations, stop-work orders, or outstanding DAS enforcement actions are attached to the equipment
DAS enforcement records
Verify any prior modernization work was permitted and closed with DAS — unpermitted work transfers as a buyer liability
Permit history • Liability transfer risk
04 Risk Flags

Post-Acquisition Risk Flags

Certificate of Operation transfers with the equipment, not the owner — buyer inherits lapsed status at closing if not resolved pre-close
Transfer mechanism • Resolve before closing
Overdue Category 3 or Category 5 tests become buyer's obligation immediately upon transfer — budget per overdue test cycle
Immediate obligation upon transfer
$2K–$8K
Service contract auto-renewal clauses may bind buyer to unfavorable terms if not renegotiated or terminated prior to closing
Contract assignability • Check notice windows
Single-bottom hydraulic cylinder replacement, if not yet completed, is a non-discretionary capital expenditure under current CT law — obtain written seller disclosure and independent cost estimate before closing
Non-discretionary • Obtain seller disclosure
$15K–$60K
Undisclosed modernization estimates from the seller's service company represent contingent capital exposure — request all written communications between seller and elevator service vendor for the prior 24 months
Seller disclosure • Request prior 24 months of vendor communications

Save this checklist as PDF