Code Adoption

Current Code
ASME A17.1-2016
Prior Code
ASME A17.1-2004 (with 2005 addendum) from May 30, 2007 to April 29, 2020; ASME A17.1-1996 from July 1, 1999 to May 30, 2007
Effective Date
April 30, 2020
State Amendments
Yes

Missouri adopts ASME A17.1-2016 effective April 30, 2020. Previous editions applied to equipment installed during different time periods. QEI certification is MANDATORY for inspectors. Missouri operates elevator registration system with Division of Fire Safety.

Governing Authority

Authority
Missouri Department of Public Safety, Division of Fire Safety, Elevator Safety Unit
Phone
(573) 526-3660
Email
[email protected]
Website
Official Site →
02 TESTING

Testing & Inspection Schedule

Routine Inspection
Annual (12 months)

All elevators must be inspected annually by Missouri state-licensed inspector. Comprehensive inspection per ASME A17.1-2016 requirements. Equipment must be registered with Division of Fire Safety. Annual testing by qualified person witnessed by state licensed inspector.

Category 1 Test
6 months minimum interval

Category 1 periodic test per ASME A17.1-2016 covering basic examination of essential components. Minimum 6-month intervals required.

Category 5 Test
Every 5 years

Category 5 periodic test per ASME A17.1-2016 covering comprehensive evaluation.

Additional Required Tests

Fire service functional test
Per ASME A17.1-2016 — Firefighter emergency operation verification per ASME A17.1-2016.
Applies to: Elevators with fire service capability
Certificate validity: 12 months
Certificate of operation posted in car or on platform per state regulations.
03 LICENSING

Licensing Requirements

Elevator Mechanic

Maintenance, repair, and testing of elevators

Requirements: License types: Mechanic I or II. Initial license fee: $75. License validity: 2 years. Out-of-state recognition: If requirements meet/exceed Missouri standards and license valid/not revoked.
Expires: 2-year term
Elevator Contractor

Installation, repair, and maintenance of elevators

Requirements: License types: Contractor I or II. Initial license fee: $200. Licensed by Elevator Safety Board. License validity: 2 years.
Expires: 2-year term
Elevator Inspector

Conduct inspections per ASME A17.1-2016

Requirements: Must be certified by the Elevator Safety Board. QEI certification REQUIRED or approved equivalency. Pass written examination by ASME-accredited association. Continuing education: 1 approved class annually.
Expires: Per renewal schedule
License Authority: Missouri Elevator Safety Board, Division of Fire Safety
Reciprocity: Out-of-state mechanic/contractor licenses recognized if requirements meet/exceed Missouri standards and license valid/not revoked.
04 PERMITS

Permit Requirements

New Installation
Required
Modernization
Required
Alteration
Required
Acceptance Inspection: Required — New installations and alterations must conform to ASME A17.1-2016. Permits required with plans and specifications. All elevators must be registered with Division of Fire Safety. Annual testing by qualified person witnessed by state licensed inspector.
05 ENFORCEMENT

Violations & Penalties

Operating without certificate: May result in misdemeanor criminal charges. Continued operation after notice: Criminal and/or civil penalties. Removal of notice: Criminal and/or civil penalties. See 11 CSR 40-5.110 for specific fine amounts. Consult Missouri Secretary of State website for details.

Operating Without Permit:

Unit ordered out of service; enforcement action and criminal/civil penalties.

Failed Inspection:

Deficiency notice with correction timeline. Failure to correct results in out-of-service order.

06 LEGAL

Key Statutes & Regulations

Missouri Elevator Safety Act
Enacted 1994; administered by Division of Fire Safety, Office of State Fire Marshal
View →

Regulations

11 CSR 40-5.065
Missouri Minimum Safety Codes for Existing Elevator Equipment
View →
11 CSR 40-5.100
State Operating Certificate and Local Operating Certificate
View →
11 CSR 40-5.110
Fees and Penalties
View →
11 CSR 40-5.120
Inspectors
View →

Key Notes for Missouri

Missouri adopted ASME A17.1-2016 effective April 30, 2020. QEI certification MANDATORY for all inspectors. Two pathways available (QEI or Candidate track). Contact: Missouri Department of Public Safety, Division of Fire Safety, Elevator Safety Unit, Phone: (573) 526-3660, Email: [email protected], Address: 205 Jefferson St., 13th Floor, Jefferson City, MO 65101-4421. Mailing for plans: P.O. Box 844, Jefferson City, MO 65102. Online portal: mo-dfs-equipinspect.azurewebsites.net. Website: dfs.dps.mo.gov

Last verified: 2026-02-18

Does Your Contract Meet Missouri Requirements?

Our Contract Scanner checks your service agreement against Missouri's specific code requirements, inspection frequencies, and compliance standards.

Scan My Contract Free